1. Payload Overview
| Property | Value |
|---|---|
| Payload Type | LPWAN Binary Payload for Telemetry Data |
| Total Size | 19 bytes |
| Byte Order | Big-endian for multi-byte values |
| Compilation Condition | The encoder is used when CONFIG_SENTOS_HAS_NRF_CLOUD_SERVICE is disabled |
| Structure | 3-byte Sentigram telemetry header, followed by Aion telemetry fields |
2. LPWAN Binary Payload Structure
| Byte Offset | Size | Field | Type | Encoding / Scaling | Description |
|---|---|---|---|---|---|
| 0 | 1 | variant_msb | uint8 | High byte of AION_VARIANT_CODE() | Bits for module base and major version |
| 1 | 1 | variant_lsb | uint8 | Low byte of AION_VARIANT_CODE() | Minor version and subtype bits |
| 2 | 1 | uplink_counter | uint8 | Incremented per message | Uplink counter |
| 3 | 1 | id | uint8 | Lowest byte of the telemetry ID | User-defined device ID |
| 4 | 1 | internal_temperature | uint8 | Raw value = °C + 128 | Internal temperature |
| 5 | 1 | alarm | uint8 | Raw alarm bitmask | Channel-specific alarm status |
| 6 | 1 | status | uint8 | Packed status bitmask | Channel-specific status |
| 7–8 | 2 | current_ch1_mA | int16 | mA × 100 | Raw current, channel 1 |
| 9–10 | 2 | current_ch2_mA | int16 | mA × 100 | Raw current, channel 2 |
| 11–12 | 2 | lower_ch1 | int16 | Engineering value × 100 | Lower limit for Channel 1 at 4 mA |
| 13–14 | 2 | lower_ch2 | int16 | Engineering value × 100 | Lower limit for Channel 2 at 4 mA |
| 15–16 | 2 | upper_ch1 | int16 | Engineering value × 100 | Upper limit for channel 1 at 20 mA |
| 17–18 | 2 | upper_ch2 | int16 | Engineering value × 100 | Upper limit for Channel 2 at 20 mA |
3. Field Description
- Total length of payload data: 19 bytes
- All multi-byte integer values are transmitted in Big-Endian format.
- The first 3 bytes form the Sentigram telemetry header.
- The following bytes contain the AION-specific telemetry data.
- Current values are encoded with a factor of 100.
- Engineering limit values are also transmitted multiplied by a factor of 100.
© Sentinum GmbH - All rights reserved.
All content in this document, including text, tables, and images, is protected by copyright and is the property of Sentinum GmbH.
Unless otherwise stated, all images are subject to the copyright of Sentinum GmbH.
Reproduction, distribution, or use—even in part—is not permitted without express written permission.
Subject to technical changes. All information is provided without warranty.