Do you want to understand how special sensor functions such as vandalism detection or the Delta feature work?
Here you will find the documentation for generic special sensor functions
Special cross-product sensor function
Name | Products | Description |
Delta Feature | ALL | |
Vandalism detection | Apollon-Q, Neptun | |
Opening detection | Apollon-Q, Neptun | |
Double Tap | Febris |
Function: Delta features
Let's assume that the sensor measures and transmits at 12:00 and is in the default settings (_property_meas_period = 30, _property_alarm_pause = 6). At 12:10 the level changes by 100mm (> _property_alarm_delta). The sensor sends the new fill level at 12:30. If nothing changes all day after 12:30, the sensor transmits at intervals of 3 hours from 12:30 (_property_alarm_pause x _property_meas_period). Measurements are still taken every half hour (property meas_period).
Function: Vandalism detection
The following parameters can be set.
Key
|
Description
|
Unite
|
r/w
|
vdetect
|
Activates vandalism detection: 0: Vandalism detection off 1: Vandalism detection on
|
rw
|
|
vdelta
|
Maximum time that may elapse between two impacts for a vandalism alarm to be triggered after the number of impacts.
|
sec
|
rw
|
vlimit
|
Number of impacts, of which a maximum of two may be within the impact delta interval for the vandalism alarm to be triggered.
|
rw
|
|
vstren
|
As soon as the acceleration is greater than the set vstren value, an impact is counted.
|
mG
|
rw
|
vcool
|
Specifies a period of time in which another vandalism alarm cannot be triggered after a vandalism alarm has been triggered.
|
min
|
rw
|
Funktion: Öffnungsdetektion (Opening Detection)
Key
|
Description
|
Unite
|
r/w
|
Open Cooldown
|
Specifies a time period in which a further opening cannot be triggered again after an opening has been triggered (debounces the openings). The last counted opening serves as a reference value. |
sec
|
rw
|
Open Alarm After
|
Indicates how long the cover must be open before an alarm is triggered |
sec
|
rw
|
Open Source
|
Indicates which source has been selected for opening detection: 0: None (opening alarm deactivated) 1: Accelerometer 2: Hall
|
rw
|
|
Magnetic Field Behaviour
|
Specifies the operating mode of the Hall sensor: 0: Container is closed when magnet is applied 1: Container is open when magnet is applied 2: Sensor counts an opening when magnet is passed twice
|
rw
|
|
Open Alarm Enable
|
Activates or deactivates the open alarm: 0: deactivated 1: activated
|
rw
|
|
Property Open Alarm Enable
|
Specifies whether an alarm is triggered after the Open Alarm After time when the container is open 0: Alarm not active 1: Alarm active
|
📢 After joining or registering, the sensor waits for the propertyopen_cooldown time until the opening counters are active. These are set to two minutes by default
Apollon-Q Flap opening detection
Flap opening detection is detected by a rotation around the x-axis.
The sensor must be mounted on the flap as follows:
A flap opening detection is detected by opening the flap as shown in the following image: