EOS Radarsensor - Configuration Parameter
Are you looking for EOS Radarsensor - Configuration Parameter?
- Timing and Alarm
- 1.1 aact Alarm Mode
- Radar
- 2.1 Additional Compile-Time Radar Setting
- LED
- 3.1 LED Indicators
- Opening / Tilt
- 4.1 Opening Mode
- Vandalism
- Trigger
- Sample Commands
EOS Resource Groups
| Module | Group | Group ID | Description |
|---|---|---|---|
| EOS | Timing and Alarm | 0x00 |
Measurement Interval and Radar Level Alarm Thresholds |
| EOS | Telemetry | 0x01 |
Read-only values after a measurement |
| EOS | Radar | 0x02 |
Radar recording and filter settings |
| EOS | LED | 0x03 |
LED Display Settings |
| EOS | Opening / Tilt | 0x04 |
Configuration for Opening and Tilt Alarms |
| EOS | Vandalism | 0x05 |
Shock-Based Vandalism Detection |
| EOS | Trigger | 0x08 |
Manual measurement trigger |
1. Timing and Alarm - Group 0x00
| Resource | ID | Description | Key | Min | Max | Factory setting | Unit | Module Key |
|---|---|---|---|---|---|---|---|---|
| Measurement period | 0x00 |
Specifies the period during which the measured values are recorded. | period |
1 | 660 | 60 | min | XXX1 |
| Delta Alarm | 0x01 |
Change in the measured distance/level since the last transmission. | delta |
0.03 | 10.0 | 3.0 | m | XXX1 |
| Regular transmission interval | 0x02 |
Number of measurements until regular transmission. | every |
1 | 24 | 1 | Measurements | XXX1 |
| Full Threshold | 0x04 |
Lower distance threshold for full/minimum detection. | full |
0.0 | 10.0 | 0.2 | m | XXX1 |
| Blank threshold | 0x05 |
Upper distance threshold for empty/maximum detection. | empty |
0.05 | 23.0 | 10.0 | m | XXX1 |
| Distance Hysteresis | 0x06 |
Hysteresis for distance alarms. | hyst |
0.0 | 1.0 | 0.5 | m | XXX1 |
| Active Radar Alarm | 0x07 |
Bit field for activating radar alarms. | aact |
0 | 7 | 0 | Bit field | XXX1 |
1.1 Alarm Mode aact - Group 0x00
Bit 0 activates the delta alarm, Bit 1 activates the min/full alarm, and Bit 2 activates the max/empty alarm.
| aact value | Delta Alarm | Min/Full Alarm | Max/Empty Alarm | Meaning |
|---|---|---|---|---|
| 0 | Off | Off | Off | No radar level alarm |
| 1 | on | off | off | Delta alarm only |
| 2 | off | on | off | Min/Full Alarm Only |
| 3 | on | on | off | Delta and Min/Full Alarms |
| 4 | off | off | on | Max/Empty alarm only |
| 5 | on | off | on | Delta and Max/Empty Alarms |
| 6 | off | on | on | Min/Full and Max/Empty Alarms |
| 7 | on | on | on | Delta, Min/Full, and Max/Empty Alarms |
2. Radar - Group 0x02
| Resource | ID | Description | Key | Min | Max | Factory setting | Unit | Module Key |
|---|---|---|---|---|---|---|---|---|
RADAR MODE |
0x00 | Radar mode: 0 = Smart Waste, 2 = Liquid. If the preset is Liquid, the default is 2; otherwise, it is 0. | tmod |
0 | 2 | 2 / 0 | enum | XXX1 |
RADAR EFFORT |
0x01 | Radar acquisition effort: 1 = low, 2 = medium, 3 = high. Higher values can improve measurement quality. | effr |
1 | 3 | 2 | enum | XXX1 |
MINIMUM RADAR MEASUREMENT DISTANCE |
0x02 | Start of the radar scan range for liquid applications. | rsta |
0.05 | 3.0 | 0.15 | m | XXX1 |
MAXIMUM RADAR MEASUREMENT DISTANCE |
0x03 | End of the radar scan range for liquid applications. | rend |
0.05 | 23.0 | 10.0 / 3.0 | m | XXX1 |
RADAR PROFILE |
0x04 | Maximum A121 radar profile for liquid applications. | prof |
1 | 5 | 2 | enum | XXX1 |
RADAR FILTER TYPE |
0x05 | Slow filter for the measured value: 0 = off, 1 = IIR, 2 = moving average, 3 = adaptive EMA. | rsft |
0 | 3 | 2 | enum | XXX1 |
RADAR FILTER DEPTH |
0x06 | Number of historical values used for the slow filter. | rsfd |
0 | 24 | 3 | Samples | XXX1 |
SMART WASTE PRESET |
0x07 | Preset index for Smart Waste applications. | wpre |
0 | 4 | 3 | enum | XXX1 |
RADAR CONFIG BLOB |
0x08 | Binary radar configuration. Bytes 0–2 correspond to Smart-Waste seq_len, med_len, and threshold. | rcfg |
0 | 24 | empty | Bytes | XXX1 |
2.1 Additional Compile-Time Radar Settings - Group 0x02
| Kconfig Symbol | Default | Min | Max | Unit | Description |
|---|---|---|---|---|---|
CONFIG_SENTOS_EOS_RADAR_FILT_MAX_DEPTH |
12 | 6 | 24 | Samples | Template capacity of the radar signal filter |
3. LED - Group 0x03
| Resource | ID | Description | Key | Min | Max | Factory setting | Unit | Module Key |
|---|---|---|---|---|---|---|---|---|
LED MODE |
0x00 | Sets the scope of the LED indicators: 0 = off, 1 = all indicators, 2 = mandatory indicators only. | led |
0 | 2 | 2 | enum | XXX1 |
3.1 LED Indicators - Group 0x03
Mandatory indicators: Power on, Power off, BLE Advertising, BLE Connected, and Alarm. Optional indicators: Network Joined, Measurement Flash, and Always-on Status Color.
| Value | Mode | Required fields | Optional fields |
|---|---|---|---|
| 0 | Off | Disabled | Disabled |
| 1 | All | Enabled | Enabled |
| 2 | Required only | Enabled | Disabled |
4. Opening / Tilt - Group 0x04
| Resource | ID | Description | Key | Min | Max | Factory setting | Unit | Module Key |
|---|---|---|---|---|---|---|---|---|
OPENING DETECTION MODE |
0x00 | Opening detection mode: 0 = off, 1 = face down, 2 = face up, 3 = vertical. | opmo |
0 | 3 | 1 | enum | XXX1 |
ALARM AFTER |
0x01 | Time after which an alarm is triggered for a permanently open state. | oaaf |
0 | 43200 | 300 | s | XXX1 |
TILT LIMIT |
0x02 | Tilt angle at which tilt detection is triggered. | ttle |
5 | 180 | 20 | deg | XXX1 |
4.1 Opening Mode - Group 0x04
| Value | Meaning |
|---|---|
| 0 | Off |
| 1 | Face down |
| 2 | Face up |
| 3 | Vertical |
5. Vandalism - Group 0x05
| Resource | ID | Description | Key | Min | Max | Factory setting | Unit | Module Key |
|---|---|---|---|---|---|---|---|---|
VANDALISM COUNT |
0x00 | Number of required impacts within the counting window. 0 disables vandalism detection. | vacn |
0 | 100 | 1 | Impacts | XXX1 |
VANDALISM THRESHOLD |
0x01 | Acceleration threshold for impact detection. | vagt |
500 | 4000 | 2000 | mg | XXX1 |
6. Triggers - Group 0x08
| Resource | ID | Description | Key | Default setting | Input | Module Key |
|---|---|---|---|---|---|---|
TRIGGER MEASUREMENT |
0x01 | Triggers an unscheduled measurement. 0x0001 activates an uplink transmission; any other value performs a local user-triggered measurement. | measure |
n/a | 2-byte big-endian command value | XXX1 |
7. Sample Commands
The following examples show typical configuration values.
Set the measurement interval to 15 minutes
Key: period
Value: 15
Set the delta alarm to 1 meter
Key: delta
Value: 1.0
Fully enable LED indicators
Key: led
Value: 1
Set the radar filter type to moving average
Key: rsft
Value: 2
Configure opening detection to "Face Up"
Key: opmo
Value: 2
Trigger manual measurement
Key: measure
Value: 0x0001
The parameters actually available depend on the firmware version, product variant, and module key.
© Sentinum GmbH - All rights reserved.
All content in this document, including text, tables, and images, is protected by copyright and is the property of Sentinum GmbH.
Unless otherwise stated, all images are subject to the copyright of Sentinum GmbH.
Reproduction, distribution, or use, even in part, is not permitted without express written permission.
Subject to technical changes. All information is provided without warranty.