Skip to content
English
  • There are no suggestions because the search field is empty.

Juno IX BSX NFC and Downlink description 

Are you looking for the Juno IX BSX NFC and downlink description? 

📄 You can view the PDF above or download it here.

Module Overview

Module Module Key Group Group ID Description
Juno 0x1XXX Timings 0x00 Defines parameters for measurements and transmission behavior.

Tables for cross-product modules (Senticom/Sentivisor) can be found in the Generic NFC and Downlink documentation

Further information on configuring sensor communication and tracking settings can be found in the respective generic LoRaWAN® or mioty® documentation, depending on the version. 

Instructions valid for versions

Article Code Features
S-JUNO-IX-LOEU-BSXINDUSTRIAL JUNO IP69k operating hours counter and TH sensor, temperature and relative humidity with magnetic field sensor LoRaWAN®
S-JUNO-IX-MIOTY-BSXINDUSTRIAL JUNO IP69k operating hours counter with vibration and magnetic field sensor mioty®
S-JUNO-IX-NBM1-BSXINDUSTRIAL JUNO IP69k operating hours counter with vibration and magnetic field sensor Cellular
S-JUNO-IX-LOEU-BSX-THINDUSTRIAL JUNO IP67 operating hours counter with vibration and magnetic field sensor LoRaWAN® – only available on request and MOQ –
S-JUNO-IX-MIOTY-BSX-THINDUSTRIAL JUNO IP67 operating hours counter with vibration and magnetic field sensor mioty® – only available on request and MOQ –
S-JUNO-IX-NBM1-BSX-THINDUSTRIAL JUNO IP67 operating hours counter with vibration and magnetic field sensor Cellular – only available on request and MOQ –

SENTIFACE: GROUP TIMINGS 0x00

Resource Resource ID Key (NFC/BLE) Min Max Factory Setting Unit Module Key
TRANSMISSION FREQUENCY 0x00 period 1 1440 60 min 1111
Specifies the regular transmission period. If there is no change in status or no alarm is triggered, the data is sent regularly at intervals specified by period.
MEASUREMENT FREQUENCY 0x01 sape 1 1000 100 ms 1111
Sampling period of the magnetic field sensor.
MEASUREMENT DURATION 0x02 sadu 1 1000 10 ms
Duration of a measurement.
ACTIVITY LIMIT VALUE 0x03 acth 0.1 10 2.5 µT RMS
Limit value at which a change of state is detected.
LIMIT VALUE HYSTERESIS 0x04 achy 0.1 10 0.3
Limit value for hysteresis used to stabilize state detection.
CUTOFF FREQ. HIGHPASS 0x05 lpfct 5 200 10 Hz
Cutoff frequency of the highpass filter.
CUTOFF FREQ. LOWPASS 0x06 hpfct 5 10 20 Hz
Cutoff frequency of the lowpass filter.
COMMAND RESET STATISTICS 0x07 rststat
Command to reset counter values. When the battery is replaced, the values are automatically reset.

Example Downlinks

Setting Downlink
period = 10 00 11 11 00 00 00 00 00 0A
acth = 5 00 11 11 00 01 00 00 00 05

Specifications subject to change without notice. All information provided without guarantee.