1. Module Overview

Module Module Key Group Group ID Description
Juno 0x1XXX Timings 0x00 Defines parameters for measurements and transmission behavior

Tables for cross-product modules (Senticom / Sentivisor) can be found in the generic NFC and downlink documentation .

Further information on configuring sensor communication and tracking settings can be found in the respective generic LoRaWAN® documentation or mioty® documentation , depending on the version.

Instructions valid for versions:

2. Versions

Article Code Features
S-JUNO-IX-LOEU-BSX INDUSTRIAL JUNO IP69k operating hours counter and TH sensor, temperature and relative humidity with magnetic field sensor LoRaWAN®
S-JUNO-IX-MIOTY-BSX INDUSTRIAL JUNO IP69k operating hours counter with vibration and magnetic field sensor mioty®
S-JUNO-IX-NBM1-BSX INDUSTRIAL JUNO IP69k operating hours counter with vibration and magnetic field sensor Cellular
S-JUNO-IX-LOEU-BSX-TH INDUSTRIAL JUNO IP67 operating hours counter with vibration and magnetic field sensor LoRaWAN® – only available on request and MOQ
S-JUNO-IX-MIOTY-BSX-TH INDUSTRIAL JUNO IP67 operating hours counter with vibration and magnetic field sensor mioty® – only available on request and MOQ
S-JUNO-IX-NBM1-BSX-TH INDUSTRIAL JUNO IP67 operating hours counter with vibration and magnetic field sensor Cellular – only available on request and MOQ

3. SENTIFACE: Timings Group 0x00

Property Property ID Description Key (NFC/BLE) Min Max Default Unit Module Key
TRANSMISSION FREQUENCY 0x00 Specifies the regular transmission period. If there is no change in status or no alarm is triggered, the data is sent regularly at intervals specified by period. period 1 1440 60 min 1111
MEASUREMENT FREQUENCY 0x01 Sampling period of the magnetic field sensor. sape 1 1000 100 ms 1111
MEASUREMENT DURATION 0x02 Duration of a measurement. sadu 1 1000 10 ms
ACTIVITY LIMIT VALUE 0x03 Limit value at which a change of state is detected. acth 0.1 10 2.5 µT RMS
LIMIT VALUE HYSTERESIS 0x04 Limit value hysteresis. achy 0.1 10 0.3
CUTOFF FREQ. HIGHPASS 0x05 Cutoff frequency highpass filter. lpfct 5 200 10 Hz
CUTOFF FREQ. LOWPASS 0x06 Cutoff frequency lowpass filter. hpfct 5 10 20 Hz
COMMAND RESET STATISTICS 0x07 Command to reset counter values (when the battery is replaced, the values are automatically reset). rststat

4. Example Downlinks

Setting Downlink
period = 10 00 11 11 00 00 00 00 00 0A
acth = 5 00 11 11 00 01 00 00 00 05
JUNO BSX Logo 1