Juno ID TILT NFC and Downlink description
Are you looking for the Juno ID TILT NFC and downlink description?
1. Version History
| Version | Date | Revision |
|---|---|---|
| 1.0.0 | 18.02.2025 | Creation |
| 1.0.1 | 24.04.2026 | Formatting, version history |
2. Module Overview
| Module | Module Key | Group | Group ID | Description |
|---|---|---|---|---|
| Sentiface | 0x1XXX |
Timings | 0x00 |
Defines parameters for measurements and transmission behavior |
| Sentiface | 0x1XXX |
Settings for opening detection | 0x02 |
Defines measurement thresholds for triggering the alarm for temperature and relative humidity |
| Sentiface | 0x1XXX |
Settings for tilt detection | 0x03 |
Defines the behavior of the acceleration sensor |
Tables for cross-product modules (Senticom / Sentivisor) can be found in the Generic NFC and Downlink documentation .
Further information on configuring sensor communication can be found in the respective generic LoRaWAN® documentation or mioty® documentation , depending on the version.
| Article Code | Features |
|---|---|
| S-JUNO-LOEU-ID | JUNO tilt sensor, tilt detection and opening detection LoRaWAN® |
| S-JUNO-IX-LOEU-ID | INDUSTRIAL JUNO tilt sensor, tilt detection and opening detection LoRaWAN® |
| S-JUNO-MIOTY-ID | JUNO tilt sensor, tilt detection and opening detection mioty® |
| S-JUNO-IX-MIOTY-ID | INDUSTRIAL JUNO tilt sensor, tilt detection and opening detection mioty® |
Instructions valid for versions listed above.
3. SENTIFACE: Timings Group 0x00
| Resources | Resource ID | Description | Key (NFC/BLE) | Min | Max | Factory Setting | Unit | Module Key |
|---|---|---|---|---|---|---|---|---|
| MEASUREMENT PERIOD | 0x00 |
Specifies the period in which the measured values are recorded. 5 minutes means that a measurement is always taken by the sensor after 5 minutes. | period |
1 / 5* | 360 | 30 | min | 1111 |
| REGULAR TRANSMISSION INTERVAL | 0x01 |
Number of measurements performed up to transmission. | every |
1 | 64 | 6 | 1111 |
*
5: For version S-JUNO-LOEU-ID and S-JUNO-MIOTY-ID
1: For version S-JUNO-IX-LOEU-ID and S-JUNO-IX-MIOTY-ID
4. SENTIFACE: Opening Detection Group 0x02
| Property | Property ID | Description | Key (NFC/BLE) | Min | Max | Default | Unit | Module Key |
|---|---|---|---|---|---|---|---|---|
| OPENING COOLDOWN | 0x00 |
Specifies a period of time in which, after the triggering of an opening, further opening cannot be triggered (debounces the openings). The reference value is the last counted opening. | acool |
0 | 600 | 0 | sec | 1111 |
| OPENING TIME ALARM | 0x01 |
Indicates how long the lid is open until an alarm is triggered. | oaaf |
0 | 2880 | 0 | sec | 1111 |
| OPENING MODE | 0x02 |
Describes which direction the sensor is facing when it is closed and
which angles are defined for opening detection.
Face up describes the status when the sensor is lying on the table
and looking up at the ceiling.
Settings 0–7 use the acceleration sensor, 8–9 use the Hall sensor: 0: Off1: Ultra low power. Fixed threshold 50°. Closed when directed downwards (face down).2: Ultra low power. Fixed threshold 50°. Closed when directed upwards (face up).3: Ultra low power. Fixed threshold 50°. Closed when directed sideways.4: Extended tilt sensing. Adjustable threshold. Closed when directed downwards.5: Extended tilt sensing. Adjustable threshold. Closed when directed upwards.6: Extended tilt sensing. Adjustable threshold. Closed when directed sideways.7: Extended tilt sampling. Adjustable threshold. Automatic calibration of the closed alignment.8: Container is closed when solenoid is applied.9: Container is open when solenoid is applied.
|
opmo |
0 | 8 | 1 | 1111 |
5. SENTIFACE: Advanced Inclination Settings Group 0x03
| Property | Property ID | Description | Key (NFC/BLE) | Min | Max | Default | Unit | Module Key |
|---|---|---|---|---|---|---|---|---|
| SAMPLING PERIOD | 0x00 |
Specifies how often the acceleration sensor determines the angle. The higher the frequency, the higher the power consumption. | tspe |
2 | 600 | 2 | s | 1111 |
| TRIGGER LEVEL | 0x01 |
Specifies the angle from which an opening is counted or an alarm is triggered. | ttle |
5 | 180 | 20 | ° | 1111 |
| TRIGGER HYSTERIA | 0x02 |
Hysteresis value for the opening angle. | tthy |
1 | 90 | 4 | ° | 1111 |
6. Example Downlinks
| Setting | Downlink |
|---|---|
period = 10 |
00 11 11 00 00 00 00 00 0A |
every = 5 |
00 11 11 00 01 00 00 00 05 |
alarm_act = 0 |
00 11 11 01 00 00 00 00 00 |
© Sentinum GmbH – All rights reserved.
All contents of this document, including text, tables and images, are protected by copyright and are the property of Sentinum GmbH.
All images are subject to the copyright of Sentinum GmbH unless otherwise stated.
Reproduction, distribution or use — even in part — is not permitted without explicit written permission.
Specifications subject to change. All information provided without warranty.
provided without warranty.